Shock Buster GFCI
|
|
 |
|
|
|
|
|
| * |
Ground fault circuit interrupter turns regular outlets into safety outlets |
| * |
Instantly shuts off power to protect terrarium equipment from electrical damage |
| * |
Essential electrical safety equipment for reptile owners |
The Shock Buster Ground Fault Circuit Interrupters provide protection against electrical shocks and equipment damage. Five Outlet GFCI converts a single outlet into 5 safety outlets. Perfect for indoor and outdoor use, the 24" Three Outlet In-Line GFCI has a heavy-duty, 12-gauge, 3-outlet power cord and built-in GFCI protection against hazardous shock from damaged cords or exposure to water. Portable Single Outlet GFCI plugs into any 3-prong AC outlet to convert it into a safety outlet. Each Shock Buster GFCI instantly detects ground fault and shuts off power in a fraction of a second. No special installation required - simply plug your terrarium equipment into Shock Buster GFCI. Features test button, reset button, and red LED power indicator light for added safety.
Shock Buster Ground Fault Circuit Interrupters protect against:
- Frayed, damaged electrical cords
- Hazardous electrical leakage levels in appliances and tools
- Electric shock caused by appliances and tools exposed to water
How does it work?
Please click on "More Information" for operating instructions.
|
| |
Operating Instructions
- Plug GFCI into a 120 VAC power outlet.
- Verify that the red LED indicator turns on. This indicates power to the GFCI output receptacle.
- Press the test button and verify that the red LED light turns off.
- Press and release the reset button and verify that the red LED indicator turns on.
- The GFCI is now ready to use.
24" Three Outlet Inline GFCI
Specifications
- Class A GFCI, 4-6mA Trip Level
- Open neutral protection
- NEMA 5-15P and (3) 5-15R outlets
- 2 ft. 12/3 AWG SJTW cord
- 1875 watts
- UL-Listed, CUL
Features
- Provides protection for 2 and 3 wire grounded appliances and tools
- Highly visible for added safety
- Allows for Compliance to NEC Article 305-6, "Temporary Wiring" and Meets OSHA Standards for Construction Site Usage
Five Outlet GFCI
- Plug into any 3-prong dual outlet
- Converts electric outlet into safety outlets
- Ideal for family TV rooms, dens, dormitory rooms, garages, basement rec rooms
- Five outlets with Shock Buster protection
Warning:
- If the GFCI fails to trip (turn off) when the test button is pressed or fails to reset (turn on), the device is defective and should not be used.
- If the GFCI tests properly without a load applied but trips each time a load is connected, then the load has a ground fault condition and needs to be repaired or replaced. DO NOT bypass the GFCI if this condition occurs. A real shock hazard may exist.
Important Notes:
TOWER's GFCI products will provide protection against ground faults when used with a 2-wire receptacle and a 3-wire to 2-wire adapter. However, it is best to use a 3-wire grounded outlet for ground fault circuit interrupters equipped with a ground pin. It will provide additional protection against electrical shock hazards.
TOWER's GFCI products will not sense ground fault conditions on the input conductors; therefore, it is recommended that all additional extension cords should be connected to the GFCI output.
Caution:
- This device is to be used on normal distribution systems 120VAC/15AMPS 60HZ maximum.
- The GFCI is a safety device. Do not use the TEST and RESET buttons as an on/off switch.
- All Ground Fault Circuit Interrupters do not protect against electrical shock resulting from contact with both current-carrying conductors of an electrical circuit.
- Do not connect any extension cord longer than 100 feet to the GFCI output to avoid the possibility of nuisance tripping.
- Test frequently and before each use to ensure proper operation.
- Do not use where water may enter the GFCI case.
- Do not modify or immerse this device.
- Do not exceed electrical rating.
|
| | Creature Comforts | | Reptile care includes creature comforts such as their unique needs in habitat, nutrition, temperature, and lighting for a happy and healthy herp. |
| | Vary Lighting for Good Health | | Exposure to full-spectrum sunlight with UVB light enables herps to produce essential vitamins, synthesize Vitamin D, and properly use calcium. |
| | Temperature & Lighting Needs | | Your pet herp, being cold-blooded, needs to rely on you to provide an environment that allows him to stay healthy. |
| | See All Articles |
|
|
|
|
|
|
|
Protection against electrical shock and terrarium equipment damage
Please note: Return of electrical equipment to Drs. Foster & Smith for exchange or refund is limited to 60 days from the date of purchase. Beyond 60 days, please contact the manufacturer for repair or replacement as covered by the manufacturer's warranty.
|
Customers who bought this ALSO BOUGHT:(showing items - of 10)
|
EMAIL ALERTS |
Want to know if we drop the price on this item?
SIGN UP
for an easy email alert!
What are Email Alerts? Learn here.
You may end alerts at any time. | Manage alerts |
|
|
 |