EasyPro High Efficiency Stainless Steel Waterfall Pumps
|
 |
|
|
|
|
|
| * |
Professional series pond pumps for continuous water circulation |
| * |
Heavy-duty pond pumps designed for lower energy consumption |
| * |
Reliable pump performance ideal for koi ponds or driving waterfalls |
Contractors' choice for continuous and reliable submersible pump operation. These long-lasting workhorses boast lower energy consumption while ensuring high volume water movement. Professional quality Stainless Steel Pumps are great for koi ponds (20 ft cord) and the powerful Waterfall Pumps are specifically designed to maintain good water flow even at higher head pressure (30 ft cord).
| Stainless Steel Pumps |
| Model |
Max GPH |
Max Head |
Inlet/Outlet |
Watts |
Dimensions |
| 1/4 HP |
2,900 |
21 ft |
NA/2"FPT |
333 |
9-1/2" dia x 16" h |
| 1/3 HP |
3,900 |
27 ft |
NA/2"FPT |
460 |
9-1/2" dia x 16" h |
| 1/2 HP |
4,900 |
32 ft |
NA/2"FPT |
644 |
9-1/2" dia x 17-1/2" h |
| 1 HP |
5,900 |
43 ft |
NA/2"FPT |
1092.5 |
9-1/2" dia x 17-1/2" h |
| High Head Waterfall Pumps |
| Model |
Max GPH |
Max Head |
Inlet/Outlet |
Watts |
Dimensions |
| 1 HP |
8,000 |
40 ft |
NA/3" FPT |
750 |
11" dia x 18" h |
| 2HP |
12,000 |
60 ft |
NA/3" FPT |
1500 |
12" dia x 21" h |
| 3HP |
14,500 |
72 ft |
NA/3" FPT |
2200 |
12" dia x 22-1/2" h |
Please click on "More Information" for performance comparison chart and safety information.
|
|
|
| Pump Performance Chart
Compare to the Tsurumi Series Pumps
The following chart shows the direct comparison between the EasyPro TH series pumps and the discontinued series of Tsurumi Pumps.*
| Model |
HP |
Amps |
Gph Flow |
Gpm Flow |
Outlet |
Mfg Warranty |
| EasyPro TH150 |
1/4 |
2.9 |
2900 |
48 |
2" |
2 yrs |
| Tsurumi T2PU |
1/5 |
2.5 |
3000 |
50 |
2" |
2 yrs |
| EasyProTH250 |
1/3 |
4.0 |
3900 |
65 |
2" |
2 yrs |
| Tsurumi T3PN |
1/3 |
4.8 |
3600 |
60 |
2" |
2 yrs |
| EasyPro TH400 |
1/2 |
5.6 |
4900 |
82 |
2" |
2 yrs |
| Tsurumi T4PN |
1/2 |
6.4 |
4800 |
80 |
2" |
2 yrs |
| EasyPro TH750 |
1 |
9.5 |
5900 |
98 |
2" |
2 yrs |
| Tsurumi T8PN |
1 |
8.6 |
5840 |
97 |
2" |
2 yrs |
*Information provided by EasyPro.
Features
- Stainless steel motor housing
- Lightweight housing made of engineering composite with glass fiber reinforcement
- Wear-resistant nylon impeller
- Precision mechanical shaft seal
Safety Instructions
Electrical Safety
- Only use with a dedicated power outlet. Sharing the outlet with other equipment may cause over-heating and fire.
- Install the pump in accordance with all applicable safety regulations.
- Do not use without proper grounding or electrical shock may occur.
- Installation to be performed by a qualified electrician.
Power Cord Safety
- Do not use an extension cord.
- Never submerge connecting power cable plug in water.
- Do not tamper with the power cord.
- Do not use an adapter that is not grounded.
- Make sure the power cable does not become bent, twisted, abraded, or cut. Damaged power cable may cause electric leakage, shock, or fire.
- Do not allow power cable to come in contact with heated surfaces.
Installation Safety
- Do not paint casing. Overheating may occur.
- Only lift the pump, using the handle - not by power cord.
- Do not hang water pump in water. Always install on a solid, flat base in upright position.
- Install properly sized outlet adapter for pipe or hose.
- Discharge end of pipe must be above water level.
- Make sure that the power cable plug and power outlet are away from water or discharge pipe or hose.
Operation Safety
- Turn power supply or circuit breaker OFF before connecting power cable plug.
- Do not start pump operation with people near intake or outlet.
- Do not operate when suspended in air.
- Use pump ONLY for circulation, transfer, or removal of water or wastewater. Do not pump oil, saltwater, or liquid chemicals.
Caution
- Do not allow dry operation.
- Do not allow foreign objects to enter intake.
- In case of power outage, turn off power switch to avoid damage when power resumes.
- If excess vibration occurs, turn off power immediately.
Protection System
The motor has a built-in protection system. It stops the pump when overheating occurs due to excess load caused by clogging at inlet or outlet, and when fluctuations in power supply occurs.
Water Level
Never operate below minimum water level of 6" above the base. For continuous operation, a minimum water level of 14" is required.
Pump Storage
When the pump is not in use for an extended period, carefully wash and dry the pump before storing indoors. Do not leave pump outdoors in freezing conditions.
|
| Water Pump Quick Specs | | Whether you want to intall a water fountain or power your pond filtration system, our handy pond pump comparison chart will help you find the right pump. |
| | Choosing a Pump | | Pumps run 24 hours a day and are the chief piece of equipment responsible for keeping your pond healthy. Selecting the correct pump is essential for a healthy pond. Here are some tips to help you pick the perfect pump. |
| | Adding a Waterfall | | Are you considering a waterfall or stream in your backyard, but don't know where to start? Creating a plan and having the right equipment goes a long way toward saving you time and money. These tips will help you get started. |
| | See All Articles |
|
|
|
|
|
|
|
Powerful professional pond pumps
|
|
Please note: If you wish to ship items with this symbol by express service, additional shipping charges will apply during checkout.
Please note:
Oversize or heavyweight items with this symbol ship for an additional $7.99 each. Additional shipping charges will apply during checkout.
|
|
Please note: Return of electrical equipment to Drs. Foster & Smith for exchange or refund is limited to 60 days from the date of purchase. Beyond 60 days, please contact the manufacturer for repair or replacement as covered by the manufacturer's warranty.
|
Customers who bought this ALSO BOUGHT:(showing items - of 10)
|
EMAIL ALERTS |
Want to know if we drop the price on this item?
SIGN UP
for an easy email alert!
What are Email Alerts? Learn here.
You may end alerts at any time. | Manage alerts |
|
|
 |